Tornar a Working Papers

Paper #414

Títol:
Validation procedures in radiological diagnostic models. Neural network and logistic regression
Autors:
Estanislao Arana, Pedro Delicado i Luis Martí
Data:
Octubre 1999
Resum:
The objective of this paper is to compare the performance of two predictive radiological models, logistic regression (LR) and neural network (NN), with five different resampling methods. One hundred and sixty-seven patients with proven calvarial lesions as the only known disease were enrolled. Clinical and CT data were used for LR and NN models. Both models were developed with cross validation, leave-one-out and three different bootstrap algorithms. The final results of each model were compared with error rate and the area under receiver operating characteristic curves (Az). The neural network obtained statistically higher Az than LR with cross validation. The remaining resampling validation methods did not reveal statistically significant differences between LR and NN rules. The neural network classifier performs better than the one based on logistic regression. This advantage is well detected by three-fold cross-validation, but remains unnoticed when leave-one-out or bootstrap algorithms are used.
Paraules clau:
Skull, neoplasms, logistic regression, neural networks, receiver operating characteristic curve, statistics, resampling
Codis JEL:
C13, C14
Àrea de Recerca:
Estadística, Econometria i Mètodes Quantitatius
Publicat a:
Investigative Radiology, 34, 636-642, 1999